132
firmware and software revisions recorded in the first half of 2026
5
types of changes notified: hardware, firmware, software, regulatory and end of production
2
PCN reports per year, in addition to individual notifications
5 years
of support and repairs after production ends
01 What is a PCN?
A Product Change Notification is an official communication through which SENECA informs customers and distributors about a change to a product. It helps assess the impact on projects, installed systems, spare parts and certifications in advance and plan the transition.
HW
New revisions of circuit boards, components, terminal blocks, mechanical parts, labels and packaging.
FW
New features, fixes and security updates to the software running on devices.
SW
Configuration and supervision programs, device description files (GSDML, EDS) and tools.
REG
Adaptations to directives and regulations, such as the RED Delegated Act or the Cyber Resilience Act.
EOL
Products being discontinued, with last-order date and recommended replacement product.
Changes that do not affect product form, function, reliability or compliance are included in the six-monthly report, without a separate notification.
02 Context and standards
SENECA’s PCN process is part of its ISO 9001-certified Quality Management System and follows international standards for notifying changes to electronic products.
May affect form, mounting, function, performance or reliability.
Dedicated notice before the first shipment of the new version
No effect on function, interfaces, compliance or reliability.
Information included in the six-monthly report
Vulnerability fixes and cybersecurity updates.
Prompt communication, including through a security advisory
Product removed from the catalogue.
Notice stating last-order date, last delivery and replacement product
| Reference | Scope | Requirements |
|---|---|---|
| J-STD-046 JEDEC / ECIA / IPC |
Notification of product and process changes | Distinguishes major and minor changes; for major changes, it requires at least 90 days’ notice before the first shipment and customer acknowledgement. |
| J-STD-048 JEDEC / ECIA |
End-of-production notification | Specifies how to communicate end of production: affected codes, last-order date, last delivery and alternatives. |
| ISO 9001:2015 § 8.5.6 |
Change control | Review and documentation of production changes, including identification of the persons authorising them. |
| IEC 62402 | Obsolescence management | Planning the product life cycle and continuity of supply. |
| IEC 62443-4-1 | Secure development of automation products | Management of security updates and communication to users. |
| Reg. (EU) 2024/2847 Cyber Resilience Act |
Products with digital elements | Security updates throughout the support period and user information; reporting obligations from 11 September 2026. |
| Reg. (EU) 2022/30 RED Delegated Act |
Connected radio equipment | Cybersecurity requirements applicable since 1 August 2025, with new hardware and firmware revisions for affected products. |
| VDMA 24903 smartPCN |
Digital PCN format | Machine-readable structure for automated exchange of notifications between suppliers and customers. |
03 Life cycle
SENECA products have an average life cycle of 3 to 10 years, with support and repairs guaranteed for a further 5 years after production ends. Each product’s life-cycle stage is indicated on its website product page.
Active
In production and recommended for new projects. Changes are notified through PCNs.
While stocks last
Still available to order but no longer manufactured: choose the replacement for new projects.
End of production
EOL notice stating the last-order date, last delivery and replacement product.
Support
Repairs, technical support, manuals and configuration software for 5 years.
End of support
The product can no longer be repaired: SENECA recommends its successor model.
These figures are indicative and depend on component availability, technology developments and contractual terms. Longer commitments may be agreed by contract.
PDF Declaration of continuity of supply
04 Latest notifications
Loading the latest notifications… To request the updated list, write to qualita@seneca.it.
05 Archive
Search by product code, PCN number or keyword and filter by product family, change type and year. Each row shows impact, effective date and required action.
Loading the archive… To request the updated list, write to qualita@seneca.it.
The complete six-monthly register of firmware and software revisions, including minor fixes, is available on request from the Quality Department.
06 Subscription service
Subscribe free of charge: you will receive email notifications when new notices are published.
Customers with a supply agreement also receive an annual PCN declaration for purchased product codes.
Write to the Quality Department, stating your name, company and the product families or codes you are interested in.
07 FAQ
Each PCN lists the affected product codes and hardware or firmware revisions. The hardware revision is shown on the label; the firmware revision can be read using configuration software or the device’s web server. If in doubt, email qualita@seneca.it with the product code and serial number.
Not always. Each PCN specifies the required action: security fixes are recommended, while new features are only needed if you intend to use them. Before updating, always check compatibility with the hardware revision and read the release notes.
Major changes are communicated before the first shipment of the new version, in line with the principles of J-STD-046. End-of-production notices state the last-order date; security fixes are communicated without delay.
Yes. For a limited period, both the previous and new versions may be supplied. The PCN states the effective date and, when available, the first batch or serial number of the new version.
You receive an end-of-production notice with the recommended replacement product and last-order date. After production ends, SENECA provides support and repairs for a further 5 years, subject to component availability.
Yes. Upon request, the Quality Department issues a declaration for the relevant period, listing products without changes and detailing modified products with an impact assessment.
Security updates also appear in this archive. Vulnerability advisories and the reporting process are published on SENECA’s Cybersecurity page.
Archive updated as of 30 June 2026, including notifications from 2025 and the first half of 2026. The next six-monthly report is expected in January 2027.