TECHNICAL DATA
Power supply from mains | From 100-240 VAC mains via standard Micro USB battery charger |
Battery power supply | 1 Lithium Polymer (LiPo) 3400 mAh battery |
Switching on | By button or automatic (depending on the mains power supply) |
Autonomy | 4 hours (minimum at maximum load) |
Degree of protection | IP20 |
Overvoltage protection | 240 Vac max without permanent damage |
Operating temperature | -20..50°C (not charging), 0..40°C during charging |
Long-term storage temperature | 0..35°C |
Humidity | 30..90 % non-condensing |
Dimensions (WxHxD) | 96 x 171 x 44 mm |
Weight | 395 g |
Rejection | 50/60 Hz |
Sampling Frequency | 10 Hz |
Operating Modes | Meter, Generator, Datalogger, Ramps |
Memory | 16MB Flash, 8 MB RAM |
Display | 5-point capacitive touch display, TFT-LCD 262k colors, 3.5“, 53x71mm, 320x480 resolution, with backlight. |
Management systems | Touch display interface and WebServer with integrated multilingual APP (Italian, English, German, French, Spanish) |
Weight | 395 g |
Supplied with | (1) Portable case, (2) MSC-D with battery, (3) adapter, (4) USB charging cable, (5) factory calibration report, (6) test cables |
Calibration report | On request |
Certification | CE |
Standards | EN61326-1; EN61010-1 |
MEASUREMENT ACCURACY | |
Accuracy | 0.03% basic, 0.04% for current |
Resolution | 1 µA; 1 mV; 5 µV; 0.1°C; 0.1uV/V |
GENERATION ACCURACY | |
Accuracy | 0.03% basic, 0.04% for current |
Resolution | 1 µA; 1 mV; 5µV; 0.1°C; 0.02 Ohm; 0.1 uV/V; |
INTERFACES AND SIGNALS | |
Buttons | On / Off |
LED | Power on LED Battery charge status LED Datalogger on LED |
Buzzer | Buzzer to signal overload and when it is impossible to simulate the requested value. |
Standard bushings | No. 4 4mm bushings |
Thermocouple connection | Mini plug (7.9mm) for thermocouple measurement and simulation |
COMMUNICATION | |
Micro USB | For firmware updates |
Wireless | Integrated 2.4 GHz WiFi (802.11 b/g/n, up to 150 Mbps); Access Point/Station mode |
Ethernet | 1 Fast Ethernet 100 Tx port, Modbus TCP-IP protocol; max 8 TCP-IP clients, control web server |
MEASURING FUNCTIONS | |
Current | 0.1..24 mA active and passive; protection ± 28 V |
Voltage (V) | 0..26 V |
Voltage (mV) | -10mV..+90mV |
Thermocouple | Type J,K ,T, E, N, R, S, B, L |
Thermocouples (2,3,4 wires) | Pt100, Pt500, Pt1000, Cu50, Cu100, Ni100, Ni120 |
Load cell | 350 Ohm; -0.2..+3mV/V |
Pulse | Max. count 1000 Hz |
Frequency | 0.1..1000 Hz |
GENERATION FUNCTIONS | |
Current | 0.1..24 mA active and passive; protection ± 28 V |
Voltage (V) | 0.1..26 V |
Voltage (mV) | -10mV..+90mV |
Thermocouple | Type J,K ,T, E, N, R,S, B, L |
Thermoresistances (2 wires) | Pt100, Pt500, Pt1000, Cu50, Cu100, Ni100, Ni120 |
Load cell | 350 Ohm; -0.2..+3mV/V |
Pulse | Min 0.5 ms (1..24V) number of pulses can be set |
Frequency | 0.1..1000 Hz; resolution 50µs |
DATA LOGGER | |
Data logger | Yes |
Sampling time | >500 ms |
RAMP FUNCTION | |
Signal | Current/Voltage/TC/RTD/Load cell |
Functions | Single or Loop |
Type | Maximum 9 segments, ramp resolution 100ms, minimum ramp 1 second |
SETTINGS AND SIGNALS | |
Functions menu | General setup (select type of operation, type of signal, language, mains frequency 50/60Hz, std or expert mode) Measurement (select voltage / current / passive current / thermocouples / resistance thermometers / bridge / pulses) Datalogger (start/stop/pause) and data visualization Generation (selection of voltage / current / passive current / thermocouples / thermoresistances / bridge / pulses) Generation of signals in ramp mode or with presets (10 for each mode) |
Error messages | Overvoltage Voltage reading higher than 28 V Under voltage Voltage reading lower than -0.2 V Over-current Current reading higher than 24 mA Under current reading lower than -0.1 mA Resistance lower than 18 Ohm Resistance higher than 400 Ohm The load cell is not powered correctly Value flashing Voltage/current/resistance/bridge generation unsuccessful |
Manuels, prospectus
Certifications
Accessoires
Produits alternatifs
Dear Customer, please note that our offices will be closed from August 8 to August 24 due to the summer holidays. The last shipping day before the break is Wednesday, August 6. We kindly ask you to place any orders by August 5. Orders received after this deadline will be processed starting from Monday, August 25, when regular operations resume. Thank you for your cooperation.