TECHNICAL DATA
| Power supply from mains | From 100-240 VAC mains via standard Micro USB battery charger | 
| Battery power supply | 1 Lithium Polymer (LiPo) 3400 mAh battery | 
| Switching on | By button or automatic (depending on the mains power supply) | 
| Autonomy | 4 hours (minimum at maximum load) | 
| Degree of protection | IP20 | 
| Overvoltage protection | 240 Vac max without permanent damage | 
| Operating temperature | -20..50°C (not charging), 0..40°C during charging | 
| Long-term storage temperature | 0..35°C | 
| Humidity | 30..90 % non-condensing | 
| Dimensions (WxHxD) | 96 x 171 x 44 mm | 
| Weight | 395 g | 
| Rejection | 50/60 Hz | 
| Sampling Frequency | 10 Hz | 
| Operating Modes | Meter, Generator, Datalogger, Ramps | 
| Memory | 16MB Flash, 8 MB RAM | 
| Display | 5-point capacitive touch display, TFT-LCD 262k colors, 3.5“, 53x71mm, 320x480 resolution, with backlight. | 
| Management systems | Touch display interface and WebServer with integrated multilingual APP (Italian, English, German, French, Spanish) | 
| Weight | 395 g | 
| Supplied with | (1) Portable case, (2) MSC-D with battery, (3) adapter, (4) USB charging cable, (5) factory calibration report, (6) test cables | 
| Calibration report | On request | 
| Certification | CE | 
| Standards | EN61326-1; EN61010-1 | 
| MEASUREMENT ACCURACY | |
| Accuracy | 0.03% basic, 0.04% for current | 
| Resolution | 1 µA; 1 mV; 5 µV; 0.1°C; 0.1uV/V | 
| GENERATION ACCURACY | |
| Accuracy | 0.03% basic, 0.04% for current | 
| Resolution | 1 µA; 1 mV; 5µV; 0.1°C; 0.02 Ohm; 0.1 uV/V; | 
| INTERFACES AND SIGNALS | |
| Buttons | On / Off | 
| LED | Power on LED Battery charge status LED Datalogger on LED  | 
| Buzzer | Buzzer to signal overload and when it is impossible to simulate the requested value. | 
| Standard bushings | No. 4 4mm bushings | 
| Thermocouple connection | Mini plug (7.9mm) for thermocouple measurement and simulation | 
| COMMUNICATION | |
| Micro USB | For firmware updates | 
| Wireless | Integrated 2.4 GHz WiFi (802.11 b/g/n, up to 150 Mbps); Access Point/Station mode | 
| Ethernet | 1 Fast Ethernet 100 Tx port, Modbus TCP-IP protocol; max 8 TCP-IP clients, control web server | 
| MEASURING FUNCTIONS | |
| Current | 0.1..24 mA active and passive; protection ± 28 V | 
| Voltage (V) | 0..26 V | 
| Voltage (mV) | -10mV..+90mV | 
| Thermocouple | Type J,K ,T, E, N, R, S, B, L | 
| Thermocouples (2,3,4 wires) | Pt100, Pt500, Pt1000, Cu50, Cu100, Ni100, Ni120 | 
| Load cell | 350 Ohm; -0.2..+3mV/V | 
| Pulse | Max. count 1000 Hz | 
| Frequency | 0.1..1000 Hz | 
| GENERATION FUNCTIONS | |
| Current | 0.1..24 mA active and passive; protection ± 28 V | 
| Voltage (V) | 0.1..26 V | 
| Voltage (mV) | -10mV..+90mV | 
| Thermocouple | Type J,K ,T, E, N, R,S, B, L | 
| Thermoresistances (2 wires) | Pt100, Pt500, Pt1000, Cu50, Cu100, Ni100, Ni120 | 
| Load cell | 350 Ohm; -0.2..+3mV/V | 
| Pulse | Min 0.5 ms (1..24V) number of pulses can be set | 
| Frequency | 0.1..1000 Hz; resolution 50µs | 
| DATA LOGGER | |
| Data logger | Yes | 
| Sampling time | >500 ms | 
| RAMP FUNCTION | |
| Signal | Current/Voltage/TC/RTD/Load cell | 
| Functions | Single or Loop | 
| Type | Maximum 9 segments, ramp resolution 100ms, minimum ramp 1 second | 
| SETTINGS AND SIGNALS | |
| Functions menu | General setup (select type of operation, type of signal, language, mains frequency 50/60Hz, std or expert mode)  Measurement (select voltage / current / passive current / thermocouples / resistance thermometers / bridge / pulses) Datalogger (start/stop/pause) and data visualization Generation (selection of voltage / current / passive current / thermocouples / thermoresistances / bridge / pulses) Generation of signals in ramp mode or with presets (10 for each mode)  | 
| Error messages | Overvoltage Voltage reading higher than 28 V Under voltage Voltage reading lower than -0.2 V Over-current Current reading higher than 24 mA Under current reading lower than -0.1 mA Resistance lower than 18 Ohm Resistance higher than 400 Ohm The load cell is not powered correctly Value flashing Voltage/current/resistance/bridge generation unsuccessful  | 