TECHNICAL DATA

Power supply from mains From 100-240 VAC mains via standard Micro USB battery charger
Battery power supply 1 Lithium Polymer (LiPo) 3400 mAh battery
Switching on By button or automatic (depending on the mains power supply)
Autonomy 4 hours (minimum at maximum load)
Degree of protection IP20
Overvoltage protection 240 Vac max without permanent damage
Operating temperature -20..50°C (not charging), 0..40°C during charging
Long-term storage temperature 0..35°C
Humidity 30..90 % non-condensing
Dimensions (WxHxD) 96 x 171 x 44 mm
Weight 395 g
Rejection 50/60 Hz
Sampling Frequency 10 Hz
Operating Modes Meter, Generator, Datalogger, Ramps
Memory 16MB Flash, 8 MB RAM
Display 5-point capacitive touch display, TFT-LCD 262k colors, 3.5“, 53x71mm, 320x480 resolution, with backlight.
Management systems Touch display interface and WebServer with integrated multilingual APP (Italian, English, German, French, Spanish)
Weight 395 g
Supplied with (1) Portable case, (2) MSC-D with battery, (3) adapter, (4) USB charging cable, (5) factory calibration report, (6) test cables
Calibration report On request
Certification CE
Standards EN61326-1; EN61010-1
MEASUREMENT ACCURACY  
Accuracy 0.03% basic, 0.04% for current
Resolution 1 µA; 1 mV; 5 µV; 0.1°C; 0.1uV/V
GENERATION ACCURACY  
Accuracy 0.03% basic, 0.04% for current
Resolution 1 µA; 1 mV; 5µV; 0.1°C; 0.02 Ohm; 0.1 uV/V;
INTERFACES AND SIGNALS  
Buttons On / Off
LED Power on LED
Battery charge status LED
Datalogger on LED
Buzzer Buzzer to signal overload and when it is impossible to simulate the requested value.
Standard bushings No. 4 4mm bushings
Thermocouple connection Mini plug (7.9mm) for thermocouple measurement and simulation
COMMUNICATION  
Micro USB For firmware updates
Wireless Integrated 2.4 GHz WiFi (802.11 b/g/n, up to 150 Mbps); Access Point/Station mode
Ethernet 1 Fast Ethernet 100 Tx port, Modbus TCP-IP protocol; max 8 TCP-IP clients, control web server
MEASURING FUNCTIONS  
Current 0.1..24 mA active and passive; protection ± 28 V
Voltage (V) 0..26 V
Voltage (mV) -10mV..+90mV
Thermocouple Type J,K ,T, E, N, R, S, B, L
Thermocouples (2,3,4 wires) Pt100, Pt500, Pt1000, Cu50, Cu100, Ni100, Ni120
Load cell 350 Ohm; -0.2..+3mV/V
Pulse Max. count 1000 Hz
Frequency 0.1..1000 Hz
GENERATION FUNCTIONS  
Current 0.1..24 mA active and passive; protection ± 28 V
Voltage (V) 0.1..26 V
Voltage (mV) -10mV..+90mV
Thermocouple Type J,K ,T, E, N, R,S, B, L
Thermoresistances (2 wires) Pt100, Pt500, Pt1000, Cu50, Cu100, Ni100, Ni120
Load cell 350 Ohm; -0.2..+3mV/V
Pulse Min 0.5 ms (1..24V) number of pulses can be set
Frequency 0.1..1000 Hz; resolution 50µs
DATA LOGGER  
Data logger Yes
Sampling time >500 ms
RAMP FUNCTION  
Signal Current/Voltage/TC/RTD/Load cell
Functions Single or Loop
Type Maximum 9 segments, ramp resolution 100ms, minimum ramp 1 second
SETTINGS AND SIGNALS  
Functions menu General setup (select type of operation, type of signal, language, mains frequency 50/60Hz, std or expert mode)
Measurement (select voltage / current / passive current / thermocouples / resistance thermometers / bridge / pulses)
Datalogger (start/stop/pause) and data visualization
Generation (selection of voltage / current / passive current / thermocouples / thermoresistances / bridge / pulses)
Generation of signals in ramp mode or with presets (10 for each mode)
Error messages Overvoltage Voltage reading higher than 28 V
Under voltage Voltage reading lower than -0.2 V
Over-current Current reading higher than 24 mA
Under current reading lower than -0.1 mA
Resistance lower than 18 Ohm
Resistance higher than 400 Ohm
The load cell is not powered correctly
Value flashing Voltage/current/resistance/bridge generation unsuccessful

Manuels, prospectus

 
IT EN FR DE ES
Datasheet
pdf icon it pdf icon en - - -
Multifunction Calibrators
pdf icon it pdf icon en - - -
Installation Manual
pdf icon it pdf icon en pdf icon fr pdf icon de pdf icon es
User Manual
pdf icon it pdf icon en - - -

Certifications

 
FAC-SIMILE Calibration report
pdf icon Multi
CE Declaration of Conformity
pdf icon Multi
REACH and ROHS declarations
pdf icon Multi
Customs codes
pdf icon Multi
0
0
0
Dear Customer, please note that our offices will be closed from August 8 to August 24 due to the summer holidays. The last shipping day before the break is Wednesday, August 6. We kindly ask you to place any orders by August 5. Orders received after this deadline will be processed starting from Monday, August 25, when regular operations resume. Thank you for your cooperation.

 

Versions du produit

MSC-D

Multi-signal and multi-function portable smart calibrator with display

En stock ?

Accessoires

CU-A-MICROB

USB cable plug USB-A - MicroUSB-B - 5P ( KIT - USB , MY2 , Z109REGBP )

Disponible en quantité limitée ?
CE-RJ45-RJ45-R

Ethernet cable (right) ( RJ45 / RJ45 )

Disponible en quantité limitée ?