Its advanced features include automatic generation of single or looped ramps, and a data logging system that allows data to be recorded and exported in .CSV format.
Thanks to its rechargeable lithium-polymer battery, it can power external devices or sensors, making it a versatile solution suitable for a range of professional and industrial environments. Its capacity to read up to 100.000 measurements makes it ideal for maintenance, technical support, measurement and calibration laboratories, quality control, electromechanical workshops and PLC programming applications.
TECHNICAL DATA
| Mains power supply | 100-240 Vac mains supply via standard Micro USB battery charger |
| Battery power supply | 1 Lithium Polymer (LiPo) 3400 mAh battery |
| Power-on | By button or automatically (depending on the mains power supply) |
| Autonomy | 4 hours (minimum at maximum load) |
| Protection rating | IP20 |
| Overvoltage protection | 240 Vac max without permanent damage |
| Operating temperature | -20..50°C (not charging), 0..40°C while charging |
| Long-term storage temperature | 0..35°C |
| Humidity | 30..90% non-condensing |
| Dimensions (wxhxd) | 96 x 171 x 44 mm |
| Weight | 395 g |
| Rejection | 50/60 Hz |
| Sampling freq. | 10 Hz |
| Operating Modes | Meter, Generator, Data logger, Ramps |
| Memories | 16MB Flash, 8 MB RAM |
| Display | 5-point capacitive touch display, TFT-LCD 262k colours, 3.5”, 53x71mm, 320x480 resolution, with backlight. |
| Management systems | Touch display interface and WebServer with integrated multilingual APP (Italian, English, German, French, Spanish) |
| Weight | 395 g |
| Included | (1) Portable case, (2) MSC-D complete with battery, (3) adapter, 4) USB charging cable, (5) factory calibration report, (6) test cables |
| Calibration report | On request |
| Approval | CE |
| Standards | EN61326-1; EN61010-1 |
| MEASUREMENT ACCURACY | |
| Accuracy | 0,03% basic, 0,04% for current |
| Resolution | 1 µA; 1 mV; 5 µV; 0,1°C; 0,1uV/V |
| GENERATION ACCURACY | |
| Accuracy | 0,03% basic, 0,04% for current |
| Resolution | 1 µA; 1 mV; 5µV; 0,1°C; 0,02 Ohm; 0,1 uV/V; |
| INTERFACES AND INDICATORS | |
| Buttons | On / Off |
| LED | Power-on indicator LED Charged battery status indicator LED Data logger on indicator LED |
| Buzzer | Buzzer for signalling overload and inability to simulate the requested value. |
| Standard sockets | No. 4 4mm sockets |
| Thermocouple connection | Mini plug (7,9mm) for thermocouple measurement and simulation |
| COMMUNICATION | |
| Micro USB | For firmware updates |
| Wireless | Integrated 2,4 GHz WiFi (802.11 b/g/n, up to 150 Mbps); Access Point/Station mode |
| Ethernet | 1 Fast Ethernet 100 Tx port, ModBUS TCP-IP protocol; max 8 TCP-IP clients, control web server |
| MEASUREMENT FUNCTIONS | |
| Current | 0,1..24 mA active and passive; ± 28 V protection |
| Voltage (V) | 0..26 V |
| Voltage (mV) | -10mV..+90mV |
| Thermocouple | Type J,K ,T, E, N, R, S, B, L |
| RTDs (2,3,4 wires) | Pt100, Pt500, Pt1000, Cu50, Cu100, Ni100, Ni120 |
| Load cell | 350 Ohm; -0,2..+3mV/V |
| Pulse | Maximum count 1000 Hz |
| Frequency | 0,1..1000 Hz |
| GENERATION FUNCTIONS | |
| Current | 0,1..24 mA active and passive; protection ± 28 V |
| Voltage (V) | 0,1..26 V |
| Voltage (mV) | -10mV..+90mV |
| Thermocouple | Type J,K ,T, E, N, R,S, B, L |
| RTDs (2 wires) | Pt100, Pt500, Pt1000, Cu50, Cu100, Ni100, Ni120 |
| Load cell | 350 Ohm; -0,2..+3mV/V |
| Pulse | Min 0,5 ms (1..24V), settable number of pulses |
| Frequency | 0,1..1000 Hz; 50µs resolution |
| DATALOGGER | |
| Datalogger | Yes |
| Sampling time | >500 ms |
| RAMP FUNCTION | |
| Signal | Current/Voltage/TC/RTD/Load cell |
| Functions | Single or Loop |
| Type | Maximum 9 segments, 100ms ramp resolution, minimum ramp 1 second |
| SETTINGS AND INDICATORS | |
| Function menu | General setup (selection of operating type, signal type, language, 50/60Hz mains frequency, std or expert mode) Measurement (voltage / current / passive current/thermocouples/RTDs/bridge/pulses selection) Data logger (start/stop/pause) and data display Generation (voltage / current / passive current/thermocouples/RTDs/bridge/pulses selection) Signal generation in ramp mode or with presets (10 for each mode) |
| Error indications | Overvoltage Voltage reading above 28 V Under voltage Voltage reading below -0,2 V Over current Current reading above 24 mA Under current Current reading below -0,1 mA Resistance below 18 Ohm Resistance above 400 Ohm Load cell not powered correctly Flashing value Voltage/current/resistance/bridge generation failed |