TECHNICAL DATA
| Power Supply | 10..30 Vdc |
| Max Power Consumption | 2.8 W |
| Isolation | 3,500 Vac (to/from power circuits) 1,500 Vac (other circuits) |
| Status Indicators | Power supply, digital channels, wiring error, Ethernet ports activity |
| Installation category | 600 V CAT III |
| Programming | through GSDML file |
| Precision class | 0.2% for voltage/current; 0.5% for power |
| Flash memory | 8 MB |
| Network features | Dual Daisy Chain Ethernet Connection LAN fault bypass (the active connection between the two Ethernet ports of the device in case of power failure) |
| Energy features | No. 2 digital inputs @5kHz |
| Type of insertion / Connection mode | Single-phase, 3-phase 3-wire, 3-phase 4-wire, CT, CT with mV output, Rogowski transducers, Aron |
| Frontal Protection degree | IP20 |
| Mounting | DIN RAIL 35 mm guide |
| Connections | Screw terminals |
| Operating temperature | -25..+65 °C |
| Dimensions | 107x90x32 mm |
| Weight | 170 g |
| Case | PC/ABS self-extinguishing UL94-V0, black color |
| Standard | CE, UL |
| Voltage/current inputs | |
| Phase voltage measurement | Voltage: up to 600 Vac, freq. 45 ÷ 65 Hz VT with output up to 600 Vac concerning neutral |
| Phase current measurement | AT with output 1-5 A f.s. AT with output mV or Rogowski up to 250 mV |
| Integrated I/Os | |
| Digital inputs | Nr.2 activatable with voltage from 12 to 24V and 2 digital counters @ 50Hz |
| Digital outputs | Nr.2 capacity Imax = 50 mA Vmax = 28V |
| COMMUNICATION | |
| Ports | Nr.2 Ethernet Ports 100 Mbps (R203-2-x models) |
| Protocol | Profinet IO |
| Connections | Ethernet switch with Daisy Chain protection |
Tools
GSDML File
SHA256 Checksum:
161558c29fb817b776222757fc2d1e6f4158b3e3936af3f14d2a36dad21acb1d
SHA256 Checksum:
161558c29fb817b776222757fc2d1e6f4158b3e3936af3f14d2a36dad21acb1d
Firmwares
ЧЕРТЕЖИ И CAD МОДЕЛИ
Dear Customer, please note that our offices will be closed from December 24 to January 6 inclusive due to the winter holidays. The last shipping day before the break is Monday, 22nd. We kindly ask you to place any orders by December 18th. Orders received after this date may only be processed when operations resume on 7 January. Thank you for your cooperation.
Product versions
Price
R204-2-L-P
Profinet energy power meter with 2 Ethernet ports and universal input (power supply 24V)
?
€ 345,00
Price
€ 7,00
€ 100,00
€ 110,00
€ 104,00
€ 104,00
€ 113,00
€ 110,00
€ 123,00
€ 155,00
€ 168,00
€ 250,00
€ 245,00
€ 402,00
€ 123,00
€ 127,00
€ 134,00
€ 188,00
€ 111,00
€ 111,00
€ 111,00
€ 114,00
€ 114,00
€ 114,00
€ 122,00
€ 122,00
€ 127,00
€ 127,00
€ 139,00
€ 139,00
€ 142,00
€ 153,00
€ 153,00
€ 31,00
€ 34,00
€ 36,00
€ 19,00
€ 20,00
€ 20,00
€ 20,00
€ 25,00
€ 27,00
€ 28,00
€ 30,00
€ 30,00
€ 31,00

RU