| Battery power supply |
3400 mAh Lithium Polymer (LiPo) battery |
| Autonomy |
8-hour operating time (minimum @ max load), 20 hours (max) |
| Mains power supply |
230 Vac mains supply with standard power adapter and 5 V 0,5 A USB socket |
| Status LEDs |
power-on communication error BT pairing datalogger on (future) battery status |
| Isolation |
Battery-powered, intrinsically isolated instrument. No isolation from USB port |
| Overvoltage protection |
230 Vac max without permanent damage (TBC) |
| Rejection |
50/60 Hz |
| Sampling freq. |
10 Hz |
| Operating Modes |
Meter Generator (with ramp functions) Datalogger |
| Buzzer |
Buzzer for signalling overload and inability to simulate the requested value. |
| Standard sockets |
No. 4 4mm sockets |
| Thermocouple connection |
Mini plug (7,9 mm) for thermocouple measurement and simulation |
| MicroUSB port functions |
power supply FW update ModBUS communication (virtual com) |
| Wireless communication |
Bluetooth Low Energy 4.1 to Andriod or Ios Smartphones and Tablets |
| Languages available for mobile APP |
Italian, English, German, French, Spanish |
| Operating temperature |
-20..50°C (not charging), 0-45°C while charging |
| Error indications |
Overvoltage Voltage reading above 28 V Under voltage Voltage reading below -0,2 V Over current Current reading above 24 mA Under current Current reading below -0,1 mA Resistance below 18 Ohm Resistance above 400 Ohm Load cell not powered correctly Flashing value Voltage / current / resistance / bridge generation failed |
| Humidity |
30..90% non-condensing |
| Dimensions (WxHxD) |
88 x 147 x 25 mm |
| Weight |
330 g |
| Protection rating |
IP20 |
| Included |
Connection leads (4), USB-microUSB cable, mains battery charger |
| Calibration certificate |
On request |
| Approval |
CE |
| Standards |
EN61326-1; EN61010-1 |
| MEASUREMENT FUNCTIONS |
|
| Current |
0..24 mA active and passive; protection ± 28 V |
| Voltage (V) |
0,0÷27 V |
| Voltage |
-10mV÷+90mV |
| Thermocouple |
Type J,K ,T, E, N, R, S, B, L |
| RTDs (2,3,4 wires) |
Pt100, Pt500, Pt1000, Cu50, Cu100, Ni100, Ni120 |
| Load cell |
350 Ohm; -0,2÷+2,4mV/V |
| Pulse |
Maximum count 1000 Hz |
| Frequency |
0,1..1000 Hz |
| Measurement accuracy |
0,03% basic, 0,04% for current |
| Measurement resolution |
1 µA; 1 mV; 5 µV; 0,1°C; 0,1uV/V |
| GENERATION FUNCTIONS |
|
| Current |
0,1..24 mA active and passive; protection ± 28 V |
| Voltage (V) |
0,1÷24 V |
| Voltage (mV) |
-10mV÷+90mV |
| Thermocouple |
Type J,K ,T, E, N, R,S, B, L |
| RTDs (2 wires) |
Pt100, Pt500, Pt1000, Cu50, Cu100, Ni100, Ni120 |
| Load cell |
350 Ohm; -0,2..+2,4mV/V |
| Pulse |
min 0,5 ms (1..24V), configurable number of pulses |
| Frequency |
0,1..1000 Hz |
| Generation accuracy |
0,03% basic, 0,04% for current |
| Generation resolution |
1 µA; 1 mV; 5µV; 0,1°C; 0,02 Ohm; 0,1 uV/V; |
| RAMP FUNCTION |
|
| Signal |
Current/Voltage/TC/RTD/Load cell |
| Functions |
Single or Loop |
| Type |
Maximum 9 segments, 100ms ramp resolution, minimum ramp 1 second |
| DATALOGGER |
|
| datalogger |
Yes |
| sampling time |
>500 ms |