TECHNICAL DATA
| Mains power supply | 100-240 Vac mains supply via standard Micro USB battery charger |
| Battery power supply | 1 Lithium Polymer (LiPo) 3400 mAh battery |
| Power-on | By button or automatically (depending on the mains power supply) |
| Autonomy | 4 hours (minimum at maximum load) |
| Protection rating | IP20 |
| Overvoltage protection | 240 Vac max without permanent damage |
| Operating temperature | -20..50°C (not charging), 0..40°C while charging |
| Long-term storage temperature | 0..35°C |
| Humidity | 30..90% non-condensing |
| Dimensions (wxhxd) | 96 x 171 x 44 mm |
| Weight | 395 g |
| Rejection | 50/60 Hz |
| Sampling freq. | 10 Hz |
| Operating Modes | Meter, Generator, Data logger, Ramps |
| Memories | 16MB Flash, 8 MB RAM |
| Display | 5-point capacitive touch display, TFT-LCD 262k colours, 3.5”, 53x71mm, 320x480 resolution, with backlight. |
| Management systems | Touch display interface and WebServer with integrated multilingual APP (Italian, English, German, French, Spanish) |
| Weight | 395 g |
| Included | (1) Portable case, (2) MSC-D complete with battery, (3) adapter, 4) USB charging cable, (5) factory calibration report, (6) test cables |
| Calibration report | On request |
| Approval | CE |
| Standards | EN61326-1; EN61010-1 |
| MEASUREMENT ACCURACY | |
| Accuracy | 0,03% basic, 0,04% for current |
| Resolution | 1 µA; 1 mV; 5 µV; 0,1°C; 0,1uV/V |
| GENERATION ACCURACY | |
| Accuracy | 0,03% basic, 0,04% for current |
| Resolution | 1 µA; 1 mV; 5µV; 0,1°C; 0,02 Ohm; 0,1 uV/V; |
| INTERFACES AND INDICATORS | |
| Buttons | On / Off |
| LED | Power-on indicator LED Charged battery status indicator LED Data logger on indicator LED |
| Buzzer | Buzzer for signalling overload and inability to simulate the requested value. |
| Standard sockets | No. 4 4mm sockets |
| Thermocouple connection | Mini plug (7,9mm) for thermocouple measurement and simulation |
| COMMUNICATION | |
| Micro USB | For firmware updates |
| Wireless | Integrated 2,4 GHz WiFi (802.11 b/g/n, up to 150 Mbps); Access Point/Station mode |
| Ethernet | 1 Fast Ethernet 100 Tx port, ModBUS TCP-IP protocol; max 8 TCP-IP clients, control web server |
| MEASUREMENT FUNCTIONS | |
| Current | 0,1..24 mA active and passive; ± 28 V protection |
| Voltage (V) | 0..26 V |
| Voltage (mV) | -10mV..+90mV |
| Thermocouple | Type J,K ,T, E, N, R, S, B, L |
| RTDs (2,3,4 wires) | Pt100, Pt500, Pt1000, Cu50, Cu100, Ni100, Ni120 |
| Load cell | 350 Ohm; -0,2..+3mV/V |
| Pulse | Maximum count 1000 Hz |
| Frequency | 0,1..1000 Hz |
| GENERATION FUNCTIONS | |
| Current | 0,1..24 mA active and passive; protection ± 28 V |
| Voltage (V) | 0,1..26 V |
| Voltage (mV) | -10mV..+90mV |
| Thermocouple | Type J,K ,T, E, N, R,S, B, L |
| RTDs (2 wires) | Pt100, Pt500, Pt1000, Cu50, Cu100, Ni100, Ni120 |
| Load cell | 350 Ohm; -0,2..+3mV/V |
| Pulse | Min 0,5 ms (1..24V), settable number of pulses |
| Frequency | 0,1..1000 Hz; 50µs resolution |
| DATALOGGER | |
| Datalogger | Yes |
| Sampling time | >500 ms |
| RAMP FUNCTION | |
| Signal | Current/Voltage/TC/RTD/Load cell |
| Functions | Single or Loop |
| Type | Maximum 9 segments, 100ms ramp resolution, minimum ramp 1 second |
| SETTINGS AND INDICATORS | |
| Function menu | General setup (selection of operating type, signal type, language, 50/60Hz mains frequency, std or expert mode) Measurement (voltage / current / passive current/thermocouples/RTDs/bridge/pulses selection) Data logger (start/stop/pause) and data display Generation (voltage / current / passive current/thermocouples/RTDs/bridge/pulses selection) Signal generation in ramp mode or with presets (10 for each mode) |
| Error indications | Overvoltage Voltage reading above 28 V Under voltage Voltage reading below -0,2 V Over current Current reading above 24 mA Under current Current reading below -0,1 mA Resistance below 18 Ohm Resistance above 400 Ohm Load cell not powered correctly Flashing value Voltage/current/resistance/bridge generation failed |

RU