Firmware Release Notes SW01978-5.4.0.0 ====================================== Supported Products: R-PASS (C0) R-PASS (D0) SSD (B0) SSD (C0) Z-PASS1-RT (C0) Z-PASS1-RT (D0) Z-PASS2-RT-4G (D0) Z-PASS2-RT-4G-S (D0) Z-PASS2-RT-4G (D1) Z-PASS2-RT-4G-S (D1) Z-PASS2-RT-4G (E0) Z-PASS2-RT-4G-S (E0) Z-TWS4-RT-S (C0) Z-TWS4-RT-S (D0) ====================================== WARNING! - MAJOR RELEASE Firmware version 5.x can only be updated from version 4.9.0.0 or later. When updating from earlier versions, the device may freeze and become inoperable. After a factory reset, the web page and discovery tool will only be available on the LAN interface. To disable the firewall, go to Router Configuration and disable the firewall for each interface, or configure a firewall exception rule to specify which ports should be open on each interface. NEW: - Complete graphical redesign of the configuration web pages - Data Logger: Increased the number of sampling groups from 4 to 10 - MQTT: Added the “%g” (group ID) and “%G” (group label) format strings for use in the topic and payload - “SD Transfer Configuration” page: Increased the maximum value of the “SD Clean Period (days)” parameter from 180 to 365 - Updated the Seneca device database: added the new S501-45-MOD-MID device and made various other changes FIX: - Fixed the issue where, after formatting from the “SD/USB File Manager” page, the SD/USB was mounted without the correct options.