Z-NET4 1.38 Release Notes New features - Added support for the latest HW revisions for Z-PASS2-S and Z-TWS4 CPUs. - Introduced HTTPS and SFTP protocols for Straton Z-TWS4-S, Z-PASS2-S, S6001-RTU CPUs. - Remote Control functions: Increased the maximum number of variables per Data Log group from 250 to 1000. Added notice when in total the 1000 variables are exceeded in the Data Log section. Added control on the maximum number of variables when importing from CSV files. - Correct copying of events from the "Errors Log". - Opening a project created with a later version of Z-NET4 shows a warning popup. - The creation of OPC_IO.INI files for ZNET IO projects is now done automatically. - The new F32 registers for the Z-4TC module are inserted in Z-NET4. - The new chain-linked voltage registers for modules S203TA-D and S203RC-D are inserted into Z-NET4. - In the creation wizard of a new Z-NET4 project, the arrows backwards have been added. - Added the import/export CSV functions also on alarm configuration of remote control functions. - The "On Error"scan frequency has been added to the I/O module parameters. - Added Timeout parameter for TCP connection. - Project Codesys/Z-TWS5: Export from Codesys configuration. Identification of the CAN section. New configuration generation with insertion of any CAN section. Modbus generation from addresses: 0x0800 (1024) for I/O 0x3800 (14336) for Merker Diagnostics - Added new Data Recorder OPC UA. Fault Correction - Fixed an error prevented the compilation of Remote Control Functions with Straton 9.0. - Correct the scale of the analog current inputs between the I/O parameters of the Z-miniRTU. - Fixed an exception with group without associated variables in Remote Control Functions. - Fixed a problem in the "Author" property of the Z-NET4 project. - Fixed a problem that eliminated Straton project ".icd" files with IEC61850 drivers. - Fixed a problem that prevented checking the compilation errors of the Straton project from Z-NET4. - Fixed a display problem: the vertical scroll bar now appears correctly in the Router tab. - Corrected an anomaly that allowed to insert among the alarm variables also variables not existing because previously removed. - Fixed a behavior that did not allow saving OpenVPN files if the active VPN mode was not OpenVPN. - Fixed an exception generated when removed from the variable Data Log variables list that were not previously enabled. - Fixed an issue that prevented normal operation of the Z-NET4 project if it was launched with double click from the project icon. - Fixed a PIN parameter display problem that was active even with mobile network connection disabled. - Corrected the parameter "Rogowski input backbone" of the S203TA/RC-D module. - Corrected the variable size of string type variables for Shared Memory. - Fixed an APN field problem of mobile network configurations. - Fixed a problem in the Remote Control Functions that allowed the sending of a reply to an SMS command even if the number was not enabled. - Fixed a Straton code problem in the Modbus Slave code configuration Deleted functionality - Serial Ports: COM16 - USB - CPU Z-TWS4-R01 Date Recorder - Correction for writing outputs to alarm. - DR channel creation error correction in Z-NET4 with SINT and SUINT variables. - Correction of a communication error with the modules via Ethernet protocol. - Added option "Display graphic labels". - Fixed an exception on "Print Alarms" and "Print Tabular". - Added the possibility to modify units of measure and channel description. - Box for selection of all channels for export. Trend Viewer - Add an option to display Min/Max channels or not. - Selection of all channels with the necessary pens added. - Removes the limit on pens. - Tabular display of pen data (with possibility to sort rows according to some columns). - Select date and time display as start or end date. - Display of range columns and zero value only for center zero option. - The "Values Table" option in the Print Report section is disabled by default. - Fixed an error on Print Report.